General information

The PiccoLink® wireless terminal has an integrated setup in which you can set the timeout and the retries.

Each connection (=request) always starts from the radio terminal and the radio server responds to this request.

If the answer takes too long, the radio terminal signals a timeout (=time overflow). The factory setting of 1 sec. is often set too short, since it is not always guaranteed that the necessary data can be found, processed and packed as a response by the SQL server within one second.

If the answer comes too late, the radio terminal reports a timeout error. Since it is also possible that in case of a bad radio transmission the request does not reach the base station in the first place, the timeout value should not be set too high.

We recommend setting the value to max. 3 seconds.

Perform setup

Steps in short form

  1. RESET via SHIFT+Del (simultaneously)
  2. Device setup with SHIFT+0 (simultaneously)
  3. Select the"Settings" module and press OK
  4. Enter password"0000" and press OK
  5. Select RF settings and press OK
  6. "Select"Reception timelimit" and press OK
  7. Delete old value with DEL
  8. Enter the new value"3" and confirm with OK
  9. RESET via SHIFT+Del (simultaneously)

The PiccoLink® RF 601 radio terminal with the EULANDA® application menu.

1. RESET via SHIFT+Del (simultaneously)

The PiccoLink® factory default start menu is displayed. In this mode only one text can be entered or a barcode can be scanned and transmitted to the radio server. Next, the device setup is called up. This does not come from the radio server, but is integrated in the radio terminal.

2. Device setup with SHIFT+0 (simultaneously)

The PiccoLink® device setup can be reached with the key combination SHIFT+0 and you can return to a menu item after pressing ok with the button[<<]. The main menu of the device setup is displayed.< />

3. Select the"Settings" module and press OK

Select the first module point from the main menu and confirm it with OK.

Enter password"0000" and press OK

The settings in the device setup are password protected. If no password has been assigned yet, it is set to"0000". Confirm your entry with OK.

5. Select RF settings and press OK

The"Settings" module has various sub-items. Select the item "RF Settings" and confirm with OK.

6. Select "Reception timelimit" and press OK

Various settings can be made via the "RF-settings" item. The timeout is set via "Reception timelimit". Select this item and confirm with OK.

7 Delete old value with DEL

You can delete the old value by pressing the DEL key.

Enter the new value"3" and confirm with OK.

Confirm the entry of the new value of"3" with OK.

9. RESET via SHIFT+Del (simultaneously)

Then perform a device reset with the combination SHIFT+DEL. Press both keys simultaneously and

the start menu described above will be displayed. When the EULANDA® radio server is active, you can call up the EULANDA® menu by pressing "F1".